5 SIMPLE TECHNIQUES FOR DP50RB

5 Simple Techniques For Dp50rb

5 Simple Techniques For Dp50rb

Blog Article

The user isn't allowed to open up the addresses and panel with the procedure, neither Observe: system disassemble is allowed. To make sure the process overall performance and security, only Mindray engineers or engineers authorized by Mindray can carry out routine maintenance.

The DP-fifty Skilled is undoubtedly an progressive, higher-performance Ultrasound Process engineered that will help you obtain the insights you would like. The Process’s powerful motor and higher-speed processing deliver exceptional graphic quality and a complete information and facts management Remedy.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat depth login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Be aware: Be sure that you could pull out and push into your IO board sockets vertically when pulling out and assembling the IO board assembly to the placement in the handle. Remove panhead screws with washers M3X6 (four) used to secure the IO board, then you could possibly choose out the IO board. Site 116 Take away panhead screws with washers (two M3X6) which might be set on the primary unit, choose out the upper baffle and afterwards pull out two cables connecting the most crucial board to the power module assembly.

Webpage 145 Clean user interface Equipment: dry gentle fabric, gentle soapy h2o  System:  Use dry comfortable fabric to clean the floor in the system. Should the technique is filthy, moisten the delicate fabric with moderate soapy drinking water and wipe off any stains. Use dry smooth fabric to get rid of any humidity and allow all challenging surfaces to absolutely air-dry. Web site 146: Clean up The Peripherals

Do not use any cables apart from the cables furnished With all the system by Mindray. 3. Utilize the cable furnished with This technique to attach the printer. Other cables may well end in electrical shock. Site 15: Mechanical Basic safety

Efficiency Test five.five.1 Examination Course of action Resolution Detection depth Geometric Placement Precision Blackout place examination Report the exam illustrations or photos 5.five.2 Exam Content The graphic made use of here is just for reference, stick to the impression impact in the true Notice: condition. Demands: Screen: set the distinction and brightness with the medical software worth (or maybe the default position) Procedure setting: dark home, simulating the scientific application natural environment. Site 76 In ailment the transverse resolution screening targets are horizontally displayed, file the nominal distance of two targets that can be clearly regarded. Repeat the Procedure higher than for that transverse resolution screening targets at other depths. As shown in determine under. Axial resolution ... Website page 77 When utilizing the convex probe, maintain the transverse resolution testing targets to notice: be displayed near the midline. When using a linear probe with steer function, usually do not turn on the steer functionality when accomplish the transverse resolution take a look at. Zoom while in the area exactly where the targets Positioned if essential. The diameter with the concentrate on position at a specific depth is equivalent to your transverse resolution at the depth. Website page 78 five.

five.two.three Geometric positioning precision Longitudinal geometric positioning precision  Exam Stage: Do adjustments as the best way in testing the most depth. Document the distance by 20mm Each and every segment around the longitudinal targets line utilizing the measurement caliper; Find the worth with the greatest error (to 20mm), calculate the precision utilizing the system underneath The measurement caliper really should be positioned within the higher fringe of the focus on, Notice:... Web page seventy nine Transverse geometric positioning accuracy  Exam Phase: Include the scan area of your phantom with water or pair gel, Carefully Call the probe With all the scan floor Adjust the depth, building the transverse targets for being shown in the picture. Change the main target level to become posited beside the transverse targets (the typical is not very clear) Alter parameters like achieve, TGC, earning Every single transverse targets being Dp50rb login Plainly shown. Webpage 80 five.5.two.4 Blackout Region Test Move: Address the scan floor on the phantom with water or pair gel, gently Get hold of the probe While using the scan area Regulate the depth at a lower worth, and established the focus at the nearest destination to the scan surface area. Minimize the value of parameters like AP, Gain right until the track record sound just could be seen. Site eighty one: Application Upgrade And Upkeep

Notice: Before uploading the log, be certain the ultrasound program is linked to community, or else, the program might warn “could not hook up with server” The server (smtp.

Help 4D probe; identify the probe through the ID code; switch the 4D push signal by using the  electrical relay to help make the 4D probe do the job Ordinarily. 4.two.two Principal board The leading board might be divided into two pieces: front-close of the principle board and back-conclude of the primary board.

Return on the procedure preset interface. The choice position alterations into Uninstalled. The uninstalling purpose is special to inner people.

This handbook may well referring to facts secured by copyright or patents and won't convey any license underneath the patent legal rights or copyright of Mindray, or of Other individuals. Webpage nine: Statement

A sensible new shape, enhanced mobility and easy Procedure make DP-fifty well suited for all clinical settings.

Your Resource for further biopsy: enabling adjustments into the scan line to gain improved visibility in the needle, nerves and smaller vessels, guaranteeing the continuity of all data.